RBBB
Technical documentation
Complete Right Bundle Branch Block
The right ventricle does not receive impulse via the right bundle branch and activates late, cell-to-cell across the septum from the left ventricle. QRS duration ≥ 120 ms with typical rSR' ('rabbit ears') pattern in V1-V2 and wide, slurred S wave in I, aVL, and V6. Secondary repolarization changes in right precordial leads.
Also known as: Complete Right Bundle Branch Block · bloqueo de rama derecha · BRD · bloqueo completo de rama derecha · bloqueo de rama derecha del haz de His · right bundle branch block · RBBB · complete RBBB
What parameters does the model use?
The following values are applied by the simulation engine to this entity. They govern activation kinematics in the 3D model and the real-time synthesis of the 12-lead electrocardiogram.
What parameters does the model use?
| Parameter | Model value |
|---|---|
| Mechanism | Bloqueo |
| Impulse origin | Sinoatrial node (SA node) |
| Modeled rate | 60–100 bpm (default 75) |
| Regularity | Regular |
| P wave | Sinus (upright in I, II, aVF) |
| PR interval | 120–200 ms (default 160) |
| QRS duration | 135 ms |
| QRS morphology | Right bundle branch block morphology |
| AV conduction | 1:1 AV conduction |
| Severity | Benign |
Which leads should be evaluated?
The catalog marks as primary diagnostic leads V1, V2, I, aVL, V6. rSR' pattern ('rabbit ears') in V1-V2; wide slurred S wave in leads I, aVL, and V6.
In the simulator, these leads are highlighted on the 12-channel tracing and corresponding vectors are rendered on the 3D model, displaying electrical changes and anatomical origin simultaneously.
Frequently asked clinical questions
How is Complete Right Bundle Branch Block identified on the 12-lead ECG?
The right ventricle does not receive impulse via the right bundle branch and activates late, cell-to-cell across the septum from the left ventricle. QRS duration ≥ 120 ms with typical rSR' ('rabbit ears') pattern in V1-V2 and wide, slurred S wave in I, aVL, and V6. Secondary repolarization changes in right precordial leads. The characteristic diagnostic waveforms are generated in real time across the simulated 12-lead tracing.
Which leads are critical for diagnostic confirmation?
The primary diagnostic leads are V1, V2, I, aVL, V6. rSR' pattern ('rabbit ears') in V1-V2; wide slurred S wave in leads I, aVL, and V6. In the simulator, these channels highlight the correlation with anatomical vectors.
What is the underlying electrophysiological or anatomical mechanism?
It originates from altered conduction in the SA_NODE, mediated by bloqueo.
How can this condition be explored in the 3D simulator?
MioAtlas offers direct deep-link reproducibility with preconfigured parameters, allowing full 3D cardiac rotation and lead vector inspection.
How do you open this configuration?
The simulator encodes its full state in the query string, providing a stable and reproducible URL:
https://mioatlas.com/simulador/en/?mode=conduction&arr=RBBB&add=1
Related entities
Other entities in the same category within the catalog:
Related clinical comparisons
Sources and bibliographic references
-
Surawicz B, Childers R, Deal BJ, et al. (2009). "AHA/ACCF/HRS recommendations for the standardization and interpretation of the electrocardiogram: Part III: Intraventricular conduction disturbances". Circulation.
-
Anderson RH, Yanni J, Boyett MR, Chandler NJ, Dobrzynski H (2009). "The anatomy of the cardiac conduction system". Clin Anat.
-
Kligfield P, Gettes LS, Bailey JJ, et al. (2007). "Recommendations for the standardization and interpretation of the electrocardiogram: Part I: The electrocardiogram and its technology". Circulation.