Atrial Arrhythmias MAT Technical documentation

Multifocal Atrial Tachycardia

Supraventricular tachycardia characterized by ≥ 3 distinct P wave morphologies in the same lead, with irregular PP, PR, and RR intervals. Typical in elderly patients with acute pulmonary disease exacerbation (COPD), hypoxia, hypercapnia, or theophylline toxicity.

Generated from the computational engine catalog · Educational reference without specialist cardiology review.

Also known as: Multifocal Atrial Tachycardia · taquicardia auricular multifocal · taquicardia auricular caotica · multifocal atrial tachycardia · MAT · TAM

What parameters does the model use?

The following values are applied by the simulation engine to this entity. They govern activation kinematics in the 3D model and the real-time synthesis of the 12-lead electrocardiogram.

What parameters does the model use?

Parameter Model value
Mechanism Automatismo
Modeled rate 100–180 bpm (default 130)
Regularity Irregular
P wave Multifocal (≥ 3 morphologies)
PR interval 100–220 ms (default 150)
QRS duration 90 ms
QRS morphology Normal (narrow)
AV conduction Variable
Severity Clinically significant

Which leads should be evaluated?

The catalog marks as primary diagnostic leads II, V1. Three or more distinct P wave morphologies with variable PP/PR intervals in II and V1.

In the simulator, these leads are highlighted on the 12-channel tracing and corresponding vectors are rendered on the 3D model, displaying electrical changes and anatomical origin simultaneously.

Frequently asked clinical questions

How is Multifocal Atrial Tachycardia identified on the 12-lead ECG?

Supraventricular tachycardia characterized by ≥ 3 distinct P wave morphologies in the same lead, with irregular PP, PR, and RR intervals. Typical in elderly patients with acute pulmonary disease exacerbation (COPD), hypoxia, hypercapnia, or theophylline toxicity. The characteristic diagnostic waveforms are generated in real time across the simulated 12-lead tracing.

Which leads are critical for diagnostic confirmation?

The primary diagnostic leads are II, V1. Three or more distinct P wave morphologies with variable PP/PR intervals in II and V1. In the simulator, these channels highlight the correlation with anatomical vectors.

What is the underlying electrophysiological or anatomical mechanism?

It originates from altered conduction in the cardiac conduction system, mediated by automatismo.

How can this condition be explored in the 3D simulator?

MioAtlas offers direct deep-link reproducibility with preconfigured parameters, allowing full 3D cardiac rotation and lead vector inspection.

How do you open this configuration?

The simulator encodes its full state in the query string, providing a stable and reproducible URL:

https://mioatlas.com/simulador/en/?mode=conduction&arr=MAT

Related entities

Other entities in the same category within the catalog:

Sources and bibliographic references

  1. Anderson RH, Yanni J, Boyett MR, Chandler NJ, Dobrzynski H (2009). "The anatomy of the cardiac conduction system". Clin Anat.
  2. Kligfield P, Gettes LS, Bailey JJ, et al. (2007). "Recommendations for the standardization and interpretation of the electrocardiogram: Part I: The electrocardiogram and its technology". Circulation.